Inorganic Ventures - We flex to your specs
Analytical Periodic Table  
 Home   Ordering   Tech Center  Inorganic Ventures and inorganic CRM's  Quotations  Inorganic Ventures and inorganic CRM's
Sign In | Register  Find out more on this analytical standards or certified reference material from IV Labs! Search   
 Guides & Articles   Periodic Table   Expert Advice    Links   Technical Support 
You are Here:  Tech Center > Guides and Articles > Silver Stability Facts
  Technical Guides
 
ICP Operations
Reliable Measurements
Sample Introduction for ICP-MS and ICP-OES
Elemental Analysis of Zeolites
Silver Stability Facts
Pure Chlorite Developed by IV
Mercury Stability Facts
Part-Per-Billion Stability Study
Understanding Error Budgets
 
  Consumer Guides
 
Flexible Expiration Dates?
Investigate Credentials Before You Buy
What Makes a Site Secure?
Hazardous Shipping Guide
Certificate of Analysis Components
Expiration Facts You Should Know
Regulating Hazardous Materials
Credit Card Advantage
Shelf Life vs. Expiration Date
 
  Quality Management
 
NIST Traceability
ISO Simplified
Transition From QS-9000 to ISO/TS 16949:2000
Lean Operations to Trim Expenses
Impressions of Southeast Asia's Quality System
 
  Editorials and More
 
New Evaporation Device Shows Promise
Site More Friendly to Users
Industry After September 11th
Ion Chromatography SRMs in Danger
 
Silver Stability Facts

By Paul Gaines, Ph.D.  •  Edited by Brian Brolin


Silver (Ag)

Many chemists often ask us about Ag chemistry. The fact is that silver is a relatively trouble-free element, provided it is kept away from HCl. We tend to keep Ag+ solutions in nitric acid because these solutions are stable to photo-reduction. However, when HCl is added, two things can occur. First, you may get precipitation if modest amounts of HCl are present. Second, with higher amounts of HCl you form a soluble chloride complex which will undergo photo-reduction to the metal. This occurs at a rate that is proportional to the amount of light exposure.

Tips When Using an HCl Matrix

If you must use an HCl matrix, here are some important tips:

  1. Keep the HCl content high (2-10% v/v).

  2. Keep the Ag+ concentration low (0.5 µg/mL).

  3. Keep the exposure to light at a minimum.

  4. The solution should be kept for no more than 5 months.

These lower levels of Ag+ are typically not a problem since modern ICP-OES instrumentation is so very sensitive and Ag+ itself is also quite sensitive. If you use glassware exposed to Ag+ + HCl, you should keep it isolated to avoid Ag+ contamination when using HNO3 matrices. These simple precautions along with the analytical properties listed below should make your analyses of Ag+ go much smoother.

Analytical Properties of Ag

Chemical Compatibility:  Stable in HNO3 and HF. Avoid basic media. Ag forms more insoluble salts than any other metal. It also is subject to photochemical reduction to the metal in HCl media although 10 µg/mL solutions in 10% HCl [AgClx1-x] are commonly used in the analytical laboratory. The most common solubility problems exist with arsenate, arsenite, bromide, chloride, iodide, carbonate, chromate, cyanide, iodate, oxalate, oxide, sulfate, sulfide, tartrate, and thiocyanate in aqueous media. The addition of nitric acid renders many of these salts soluble.

Stability:  2-100 ppb levels stable for 75+ days when mixed with equivalent levels of all other elements including the precious metals (where chloride is present) when in 1% HNO3 / LDPE container. 1-10,000 ppm solutions chemically stable for years in 1-5% HNO3 / LDPE container.

Ag Containing Samples (Preparation & Solution):  Metal (soluble in HNO3); Oxides (soluble in HNO3); Ores (digestion with conc. HNO3).

Visit our Analytical Periodic Table for the analytical properties of over seventy elements. 