Inorganic Ventures - We flex to your specs
Guide to Reliable Measurements  
 Home   Ordering   Tech Center  Inorganic Ventures and inorganic CRM's  Quotations  Inorganic Ventures and inorganic CRM's
Sign In | Register  Find out more on this analytical standards or certified reference material from IV Labs! Search   
 Guides & Articles   Periodic Table   Expert Advice    Links   Technical Support 
You are Here:  Tech Center > Expert Advice > Eliminating High and Erratic Blanks
  General Applications
 
Certified Concentration of a Standard
Nitric Acid Oxidations
Two Methods for Certification
ICP-MS Sensitivity Optimization
Cleaning Quartzware
 
  Sample Preparation
 
Dissolving Graphite to Measure by ICP
Quartz Powder Preparation
XRF vs. ICP for Concrete Metals
Dissolution of Si in Metals
Analysis of Sediment Samples
Reactions of Sulfur and Bromine
Determination of As in Sediment
Matrices for Soil Preparation
Trace Metal Analysis of Air Condensate
Analyzing Cement
Determination of Hg in Sediment
Sample Size for Steel Analysis
Analyzing For Br by ICP
Analytical Tips for Tin
Analyzing Silicone Oils
Ashing Technique for Metals
Coal Sample Digestions
Ashing Procedure For Tin
Using Blue HDPE Containers
Sn and Tl Soil Extraction
Filter Papers for EPA Method 353.2
Determination of Hg in Biological Matrices
 
  Stability & Compatibility
 
Eliminating High and Erratic Blanks
HF in Multi-element Standards
Chemical Stability of Standards
Questions About Mo, Ti, and Hg
Overcoming Au Stability Issues
Contaminants of Ethanol in HDPE
Vegetable Oil Stability
ICP Multi-Element Solution Incompatibilities
Multi-Element Compatibility and Preparation
Stability of Mercury in Plastic Bottles
Cadmium, Lead, and Copper Stability
Diluted Blends of Single Element Standards
Incompatible Metals Within Solution
Stability of Oil Standards
 
  Measurement
 
ICP: Applying F Test Results
Controlling Transpiration
Calculating Weighing Uncertainty
Expressing Sensitivity
As Line Interferences from Fe
Measurement Uncertainty
Positive Interference with Hg 202
Linearity Slope Variance
Mercury and Antimony Troubleshooting
Zn Interferences Upon the Na 330.237 nm Line
Aluminum, Beryllium, and Chromium Interferences
 
Eliminating High and Erratic Blanks Technical Troubleshooter

Who is Paul Gaines?

Guillaume contacted Paul to find out whether he knew of a published paper with the values of Reliable Measurements: Table 8.1, Effect of Laboratory Atmosphere on Pb Blank Levels. He noted that his lab was having some problems with the Pb blanks values (ICP-MS), which appeared random to him.


IV Labs / Inorganic Ventures: White Background
 
From the desk of Paul Gaines, Ph.D. Dr. Paul Gaines
  RE: Eliminating High and Erratic Blanks
Dear Guillaume,

     We used to use leaded gasoline in the USA, making ppb level Pb determinations nearly impossible. The basic rule back then was to work in the hood only if you must as it was the greatest area for contamination because of increased air exposure, but always keep the sample covered. Most contamination today is from apparatus and reagents.

     I would like to suggest that you perform blanks in and away from the hood and covered and uncovered, with varying amounts of reagents etc. in order to identify the source of contamination (air, apparatus, operator, or reagents). All four areas come into play with trace Pb determinations and each laboratory must perform their personal studies to identify, and hopefully eliminate, high and erratic blanks.

     Thank you for contacting Inorganic Ventures and for your question.

 
  Paul's signature
Paul R. Gaines, Ph.D.
Serving you in chemistry
 
IV Labs / Inorganic Ventures: White Background

An Inorganic Ventures feature - May 2008


DISCLAIMER  Advice offered by Dr. Gaines is intended for the individual posing the question. We urge you to contact us to verify whether these suggestions apply to your circumstances.
 Privacy Policy  |  Site Map   
  800.669.6799   •   540.585.3030
© 2009 Inorganic Ventures, Inc.. All rights reserved.