Inorganic Ventures - We flex to your specs
Guide to Reliable Measurements  
 Home   Ordering   Tech Center  Inorganic Ventures and inorganic CRM's  Quotations  Inorganic Ventures and inorganic CRM's
Sign In | Register  Find out more on this analytical standards or certified reference material from IV Labs! Search   
 Guides & Articles   Periodic Table   Expert Advice    Links   Technical Support 
You are Here:  Tech Center > Expert Advice > Dissolving Graphite to Measure by ICP
  General Applications
 
Certified Concentration of a Standard
Nitric Acid Oxidations
Two Methods for Certification
ICP-MS Sensitivity Optimization
Cleaning Quartzware
 
  Sample Preparation
 
Dissolving Graphite to Measure by ICP
Quartz Powder Preparation
XRF vs. ICP for Concrete Metals
Dissolution of Si in Metals
Analysis of Sediment Samples
Reactions of Sulfur and Bromine
Determination of As in Sediment
Matrices for Soil Preparation
Trace Metal Analysis of Air Condensate
Analyzing Cement
Determination of Hg in Sediment
Sample Size for Steel Analysis
Analyzing For Br by ICP
Analytical Tips for Tin
Analyzing Silicone Oils
Ashing Technique for Metals
Coal Sample Digestions
Ashing Procedure For Tin
Using Blue HDPE Containers
Sn and Tl Soil Extraction
Filter Papers for EPA Method 353.2
Determination of Hg in Biological Matrices
 
  Stability & Compatibility
 
Eliminating High and Erratic Blanks
HF in Multi-element Standards
Chemical Stability of Standards
Questions About Mo, Ti, and Hg
Overcoming Au Stability Issues
Contaminants of Ethanol in HDPE
Vegetable Oil Stability
ICP Multi-Element Solution Incompatibilities
Multi-Element Compatibility and Preparation
Stability of Mercury in Plastic Bottles
Cadmium, Lead, and Copper Stability
Diluted Blends of Single Element Standards
Incompatible Metals Within Solution
Stability of Oil Standards
 
  Measurement
 
ICP: Applying F Test Results
Controlling Transpiration
Calculating Weighing Uncertainty
Expressing Sensitivity
As Line Interferences from Fe
Measurement Uncertainty
Positive Interference with Hg 202
Linearity Slope Variance
Mercury and Antimony Troubleshooting
Zn Interferences Upon the Na 330.237 nm Line
Aluminum, Beryllium, and Chromium Interferences
 
Dissolving Graphite to Measure by ICP Technical Troubleshooter

Who is Paul Gaines?

Cathy questioned Paul about whether he knew of an easy way to dissolve graphite powder to measure Al, Si, Ti, Fe, Co, Ni, Mg, Ca, and total Cr by ICP. She wondered whether there are any known interferences from the graphite that may cause problems.


IV Labs / Inorganic Ventures: White Background
 
From the desk of Paul Gaines, Ph.D. Dr. Paul Gaines
  RE: Dissolving Graphite to Measure by ICP
Dear Cathy,

Graphite is a tough one to dissolve. I believe it can be dissolved/digested using perchloric acid with vanadium added as a catalyst (addition of vanadium is very important).

The method I am most familiar with uses 1 gram of sample + 18 mL sulfuric + 15 mL conc. perchloric acid in a glass digestion flask with condenser (do not use perchloric acid in a microwave furnace under any circumstances). The condenser is needed to contain any volatiles. In addition, 10 mg of V is added as either the pentoxide or in solution form as V+5 to act as a catalyst (I use 1 mL of the Inorganic Ventures' 10,000 ug/mL Vanadium standard, which is very pure and the V is in the +5 oxidation state). I have been able to decompose even charcoal and coke using the V+5 catalyst and I suspect this method would work for graphite carbon. Finally, graphite carbon would present no spectral interferences to an ICP-OES measurement.

Please consult the Acid Digestions of Organic Samples section of our Reliable Measurements guide. The text goes into further detail on the digestion of organic matrices.

Thank you for your question and best of luck.

 
  Paul's signature
Paul R. Gaines, Ph.D.
Serving you in chemistry
 
IV Labs / Inorganic Ventures: White Background

An Inorganic Ventures feature - August 2007


DISCLAIMER  Advice offered by Dr. Gaines is intended for the individual posing the question. We urge you to contact us to verify whether these suggestions apply to your circumstances.
 Privacy Policy  |  Site Map   
  800.669.6799   •   540.585.3030
© 2009 Inorganic Ventures, Inc.. All rights reserved.