Inorganic Ventures - We flex to your specs
Guide to Reliable Measurements  
 Home   Ordering   Tech Center  Inorganic Ventures and inorganic CRM's  Quotations  Inorganic Ventures and inorganic CRM's
Sign In | Register  Find out more on this analytical standards or certified reference material from IV Labs! Search   
 Guides & Articles   Periodic Table   Expert Advice    Links   Technical Support 
You are Here:  Tech Center > Expert Advice > Sample Size for Steel Analysis
  General Applications
 
Certified Concentration of a Standard
Nitric Acid Oxidations
Two Methods for Certification
ICP-MS Sensitivity Optimization
Cleaning Quartzware
 
  Sample Preparation
 
Dissolving Graphite to Measure by ICP
Quartz Powder Preparation
XRF vs. ICP for Concrete Metals
Dissolution of Si in Metals
Analysis of Sediment Samples
Reactions of Sulfur and Bromine
Determination of As in Sediment
Matrices for Soil Preparation
Trace Metal Analysis of Air Condensate
Analyzing Cement
Determination of Hg in Sediment
Sample Size for Steel Analysis
Analyzing For Br by ICP
Analytical Tips for Tin
Analyzing Silicone Oils
Ashing Technique for Metals
Coal Sample Digestions
Ashing Procedure For Tin
Using Blue HDPE Containers
Sn and Tl Soil Extraction
Filter Papers for EPA Method 353.2
Determination of Hg in Biological Matrices
 
  Stability & Compatibility
 
Eliminating High and Erratic Blanks
HF in Multi-element Standards
Chemical Stability of Standards
Questions About Mo, Ti, and Hg
Overcoming Au Stability Issues
Contaminants of Ethanol in HDPE
Vegetable Oil Stability
ICP Multi-Element Solution Incompatibilities
Multi-Element Compatibility and Preparation
Stability of Mercury in Plastic Bottles
Cadmium, Lead, and Copper Stability
Diluted Blends of Single Element Standards
Incompatible Metals Within Solution
Stability of Oil Standards
 
  Measurement
 
Controlling Transpiration
Calculating Weighing Uncertainty
Expressing Sensitivity
As Line Interferences from Fe
Measurement Uncertainty
Positive Interference with Hg 202
Linearity Slope Variance
Mercury and Antimony Troubleshooting
Zn Interferences Upon the Na 330.237 nm Line
Aluminum, Beryllium, and Chromium Interferences
 
Sample Size for Steel Analysis Technical Troubleshooter

Who is Paul Gaines?

In low-alloy steel analysis by ICP, Ernie wanted to know what would be considered an adequate sample size in grams. He noted that the samples would be dissolved in acid under pressure in a microwave oven.


IV Labs / Inorganic Ventures: White Background
 
From the desk of Paul Gaines, Ph.D. Dr. Paul Gaines
  RE: Sample Size for Steel Analysis
Dear Ernie,

     Steels would be termed 'Compact Solids' and the mode of sampling is the first issue to be addressed, making the sample size issue more apparent. For compact solids, random sampling is suggested (random drilling where any portion of the bulk material has the same probability of being included in the sample - all of the drillings are collected). Typically it is difficult to keep the sample size smaller than 1 gram. If the sample size collected is more on the order of 50 to 500 grams (100 - 500 grams is a better situation for steels), the drillings can be mixed, pilled, and separated into quadrants and opposite quadrants taken (sample size reduction) and repeated until sample size reduction to a workable size (i.e., ~ 10 grams is achieved). Multiple 1 gram samples can then be taken (sub-sampling) from the reduced sample size for analysis.

     Therefore, the first and biggest issue is whether a representative sample was taken? Secondly, is the acceptable reduction of the sample down to the lowest workable representative 'sub-sample' size. With respect to sub-sampling errors, working with small (~0.1 gram) sample sizes for alloys such as steel is much easier for microwave digestion but has an increased risk of providing results that do not represent the sample as a whole. The above link can help you make that determination.

Please feel free to call with any questions

 
  Paul's signature
Paul R. Gaines, Ph.D.
Serving you in chemistry
 
IV Labs / Inorganic Ventures: White Background

An Inorganic Ventures feature - March 2004


DISCLAIMER  Advice offered by Dr. Gaines is intended for the individual posing the question. We urge you to contact us to verify whether these suggestions apply to your circumstances.
 Privacy Policy  |  Site Map   
  800-569-6799   •   732-901-1900
© 2008 Inorganic Ventures, Inc.. All rights reserved.