Inorganic Ventures - We flex to your specs
Guide to Reliable Measurements  
 Home   Ordering   Tech Center  Inorganic Ventures and inorganic CRM's  Quotations  Inorganic Ventures and inorganic CRM's
Sign In | Register  Find out more on this analytical standards or certified reference material from IV Labs! Search   
 Guides & Articles   Periodic Table   Expert Advice    Links   Technical Support 
You are Here:  Tech Center > Expert Advice > XRF vs. ICP for Concrete Metals
  General Applications
 
Certified Concentration of a Standard
Nitric Acid Oxidations
Two Methods for Certification
ICP-MS Sensitivity Optimization
Cleaning Quartzware
 
  Sample Preparation
 
Dissolving Graphite to Measure by ICP
Quartz Powder Preparation
XRF vs. ICP for Concrete Metals
Dissolution of Si in Metals
Analysis of Sediment Samples
Reactions of Sulfur and Bromine
Determination of As in Sediment
Matrices for Soil Preparation
Trace Metal Analysis of Air Condensate
Analyzing Cement
Determination of Hg in Sediment
Sample Size for Steel Analysis
Analyzing For Br by ICP
Analytical Tips for Tin
Analyzing Silicone Oils
Ashing Technique for Metals
Coal Sample Digestions
Ashing Procedure For Tin
Using Blue HDPE Containers
Sn and Tl Soil Extraction
Filter Papers for EPA Method 353.2
Determination of Hg in Biological Matrices
 
  Stability & Compatibility
 
Eliminating High and Erratic Blanks
HF in Multi-element Standards
Chemical Stability of Standards
Questions About Mo, Ti, and Hg
Overcoming Au Stability Issues
Contaminants of Ethanol in HDPE
Vegetable Oil Stability
ICP Multi-Element Solution Incompatibilities
Multi-Element Compatibility and Preparation
Stability of Mercury in Plastic Bottles
Cadmium, Lead, and Copper Stability
Diluted Blends of Single Element Standards
Incompatible Metals Within Solution
Stability of Oil Standards
 
  Measurement
 
Controlling Transpiration
Calculating Weighing Uncertainty
Expressing Sensitivity
As Line Interferences from Fe
Measurement Uncertainty
Positive Interference with Hg 202
Linearity Slope Variance
Mercury and Antimony Troubleshooting
Zn Interferences Upon the Na 330.237 nm Line
Aluminum, Beryllium, and Chromium Interferences
 
XRF vs. ICP for Concrete Metals Technical Troubleshooter

Who is Paul Gaines?

Theresa recently asked which results tend to be more accurate for metals in concreate: XRF or ICP. She explained that she uses ICP and ICP-MS and has often compared her values to other analysts' XRF values and they never agreed. She noted that her laboratory usually does a borate powder press when they do XRF and then performs a standardless analysis.


IV Labs / Inorganic Ventures: White Background
 
From the desk of Paul Gaines, Ph.D. Dr. Paul Gaines
  RE: XRF vs. ICP for Concrete Metals
Dear Theresa,

     EDXRF and/or Wavelength XRF suffer from matrix and interelement interference issues, as does ICP (OES and MS). With XRF, the standard and sample must be matrix matched with respect to both the matrix and the particle size. In addition, I have seen that different chemical forms can cause problems such as alkyl Si versus Si oxides in an organic matrix, i.e. the elemental composition is similar, yet results for the methyl silicon are much lower than oxygenated silicon due to scattering. Furthermore, the analyte emission intensity is enhanced by matrix elements lower in atomic number and suppressed by analytes higher in atomic number.

     With respect to Cements by XRF, it is possible to fuse them into a glass using lithium borate/carbonate. This eliminates the physical interferences and leaves the analyst to make corrections on the interelement effects - calculations are involved and not perfect. The standardless XRF determinations were started 20+ years ago and I have tried it. The common term then was 'MARS' (Matrix Analysis Routine using Scatter). It is an approach that I found to give reasonable results provided that major components are of prime interest and agreements to around 10 to 15 % relative are acceptable. I have used MARS for screening and semi-quantitative analysis (I love math and physics and this technique attracted me for those reasons, plus it was new at the time) but the ICP-OES approach has the potential for giving very accurate and precise results. Using the lithium borate fusion-dissolution in dilute nitric acid (matrix matched at this point) and using lines that do not spectrally interfere, the ICP-OES technique can do this while XRF cannot. With XRF, the analyst is stuck making corrections that contain a level of uncertainty.

     In short, I would choose ICP-OES over ICP-MS and XRF because the systematic errors are much easier to eliminate and the random measurement error can be as low as 0.5 %. (XRF can do better with respect to precision, but who need a very precise "wrong" answer?)

Let me know if you have any other questions.

 
  Paul's signature
Paul R. Gaines, Ph.D.
Serving you in chemistry
 
IV Labs / Inorganic Ventures: White Background

An Inorganic Ventures feature - February 2006


DISCLAIMER  Advice offered by Dr. Gaines is intended for the individual posing the question. We urge you to contact us to verify whether these suggestions apply to your circumstances.
 Privacy Policy  |  Site Map   
  800-569-6799   •   732-901-1900
© 2008 Inorganic Ventures, Inc.. All rights reserved.