Inorganic Ventures - We flex to your specs
Guide to Reliable Measurements  
 Home   Ordering   Tech Center  Inorganic Ventures and inorganic CRM's  Quotations  Inorganic Ventures and inorganic CRM's
Sign In | Register  Find out more on this analytical standards or certified reference material from IV Labs! Search   
 Guides & Articles   Periodic Table   Expert Advice    Links   Technical Support 
You are Here:  Tech Center > Expert Advice > Analyzing For Br by ICP
  General Applications
 
Certified Concentration of a Standard
Nitric Acid Oxidations
Two Methods for Certification
ICP-MS Sensitivity Optimization
Cleaning Quartzware
 
  Sample Preparation
 
Dissolving Graphite to Measure by ICP
Quartz Powder Preparation
XRF vs. ICP for Concrete Metals
Dissolution of Si in Metals
Analysis of Sediment Samples
Reactions of Sulfur and Bromine
Determination of As in Sediment
Matrices for Soil Preparation
Trace Metal Analysis of Air Condensate
Analyzing Cement
Determination of Hg in Sediment
Sample Size for Steel Analysis
Analyzing For Br by ICP
Analytical Tips for Tin
Analyzing Silicone Oils
Ashing Technique for Metals
Coal Sample Digestions
Ashing Procedure For Tin
Using Blue HDPE Containers
Sn and Tl Soil Extraction
Filter Papers for EPA Method 353.2
Determination of Hg in Biological Matrices
 
  Stability & Compatibility
 
Eliminating High and Erratic Blanks
HF in Multi-element Standards
Chemical Stability of Standards
Questions About Mo, Ti, and Hg
Overcoming Au Stability Issues
Contaminants of Ethanol in HDPE
Vegetable Oil Stability
ICP Multi-Element Solution Incompatibilities
Multi-Element Compatibility and Preparation
Stability of Mercury in Plastic Bottles
Cadmium, Lead, and Copper Stability
Diluted Blends of Single Element Standards
Incompatible Metals Within Solution
Stability of Oil Standards
 
  Measurement
 
Controlling Transpiration
Calculating Weighing Uncertainty
Expressing Sensitivity
As Line Interferences from Fe
Measurement Uncertainty
Positive Interference with Hg 202
Linearity Slope Variance
Mercury and Antimony Troubleshooting
Zn Interferences Upon the Na 330.237 nm Line
Aluminum, Beryllium, and Chromium Interferences
 
Analyzing For Br by ICP Technical Troubleshooter

Who is Paul Gaines?

Bill was analyzing for Br by ICP-OES. He had several samples in a PET matrix with Br concentrations ranging from 1-18%. Bill inquired about any recommended methods of analysis.


IV Labs / Inorganic Ventures: White Background
 
From the desk of Paul Gaines, Ph.D. Dr. Paul Gaines
  RE: Analyzing For Br by ICP
Dear Bill,

     I assume that the PET matrix referenced is 10-[3, 5-bis(methoxycarbonyl) phenoxy] decyltriphenylphosphonium bromide. If this assumption is correct, I would like to suggest a Schoeniger (sometimes spelled Schoniger) flask combustion of the sample. This technique involves total combustion of the sample in oxygen which converts nonmetallic elements such as bromide to volatile gaseous compounds. These gases can be collected into a suitable absorbing solution which is typically analyzed by Ion Chromatography but could also be analyzed by ICP. In the case of Br (a reducing agent), typically dilute hydrazine sulfate, should be added to prevent the formation of oxyanions for bromide. In the case of an ICP analysis, this reducing agent should still be used because of the possibility of the formation of molecular bromine which will adsorb readily upon plastic surfaces.

     The use of ICP to analyze the Br is preferred because of the outside chance of other oxybromides that may be present (i.e., lower worry-factor). Please refer to the spectral data (below) which shows little to no interference from 'all' of the other elements for line 154.065 nm where we measured a DL of 0.02 ug/mL in our laboratory (i.e., a good signal for a 0.1 ppm Br solution).


Click to enlarge

Please contact me with any further questions.

 
  Paul's signature
Paul R. Gaines, Ph.D.
Serving you in chemistry
 
IV Labs / Inorganic Ventures: White Background

An Inorganic Ventures feature - February 2004