Inorganic Ventures - We flex to your specs
Guide to Reliable Measurements  
 Home   Ordering   Tech Center  Inorganic Ventures and inorganic CRM's  Quotations  Inorganic Ventures and inorganic CRM's
Sign In | Register  Find out more on this analytical standards or certified reference material from IV Labs! Search   
 Guides & Articles   Periodic Table   Expert Advice    Links   Technical Support 
You are Here:  Tech Center > Expert Advice > Expressing Sensitivity
  General Applications
 
Certified Concentration of a Standard
Nitric Acid Oxidations
Two Methods for Certification
ICP-MS Sensitivity Optimization
Cleaning Quartzware
 
  Sample Preparation
 
Dissolving Graphite to Measure by ICP
Quartz Powder Preparation
XRF vs. ICP for Concrete Metals
Dissolution of Si in Metals
Analysis of Sediment Samples
Reactions of Sulfur and Bromine
Determination of As in Sediment
Matrices for Soil Preparation
Trace Metal Analysis of Air Condensate
Analyzing Cement
Determination of Hg in Sediment
Sample Size for Steel Analysis
Analyzing For Br by ICP
Analytical Tips for Tin
Analyzing Silicone Oils
Ashing Technique for Metals
Coal Sample Digestions
Ashing Procedure For Tin
Using Blue HDPE Containers
Sn and Tl Soil Extraction
Filter Papers for EPA Method 353.2
Determination of Hg in Biological Matrices
 
  Stability & Compatibility
 
Eliminating High and Erratic Blanks
HF in Multi-element Standards
Chemical Stability of Standards
Questions About Mo, Ti, and Hg
Overcoming Au Stability Issues
Contaminants of Ethanol in HDPE
Vegetable Oil Stability
ICP Multi-Element Solution Incompatibilities
Multi-Element Compatibility and Preparation
Stability of Mercury in Plastic Bottles
Cadmium, Lead, and Copper Stability
Diluted Blends of Single Element Standards
Incompatible Metals Within Solution
Stability of Oil Standards
 
  Measurement
 
Controlling Transpiration
Calculating Weighing Uncertainty
Expressing Sensitivity
As Line Interferences from Fe
Measurement Uncertainty
Positive Interference with Hg 202
Linearity Slope Variance
Mercury and Antimony Troubleshooting
Zn Interferences Upon the Na 330.237 nm Line
Aluminum, Beryllium, and Chromium Interferences
 
Expressing Sensitivity Technical Troubleshooter

Who is Paul Gaines?

Zhongke asked Dr. Gaines about expressing sensitivity when working with ICP. Specifically, he wanted to know what is the unit of sensitivity and how sensitivity is calculated.


IV Labs / Inorganic Ventures: White Background
 
From the desk of Paul Gaines, Ph.D. Dr. Paul Gaines
  RE: Expressing Sensitivity
Dear Zhongke,

     In analytical chemistry, sensitivity is the slope of the calibration curve. For ICP applications, it is expressed in counts/concentration units. When analysts are thinking about sensitivity, they use a language that expresses sensitivity in terms of detection limits (DL) rather than sensitivity units (S = counts /conc. units). DL is used because S has little value in making relative comparisons. It is much more to the point to speak in terms of DL rather than S. However, there is a relationship between S and DL. The relationship between the two is dependent upon the definition of DL. A popular definition of DL for ICP that incorporates sensitivity (S) is:

DL = (3(std. dev. of noise in counts))/S

     Using the above equation, the DL is expressed in the concentration units of choice. Using ICP as an example, a common concentration unit is ppm = micrograms of analyte/gram solution. Therefore, an analyst will state that a technique that has a DL of 0.001 ppm is 100 times more sensitive than a technique with a DL of 0.1 ppm. On a practical level, we think of sensitivity in terms of DL, even though we need to measure S to calculate the DL.

Please do not hesitate to contact me if you need more information.

 
  Paul's signature
Paul R. Gaines, Ph.D.