Inorganic Ventures - We flex to your specs
Guide to Reliable Measurements  
 Home   Ordering   Tech Center  Inorganic Ventures and inorganic CRM's  Quotations  Inorganic Ventures and inorganic CRM's
Sign In | Register  Find out more on this analytical standards or certified reference material from IV Labs! Search   
 Guides & Articles   Periodic Table   Expert Advice    Links   Technical Support 
You are Here:  Tech Center > Expert Advice > Measurement Uncertainty
  General Applications
 
Certified Concentration of a Standard
Nitric Acid Oxidations
Two Methods for Certification
ICP-MS Sensitivity Optimization
Cleaning Quartzware
 
  Sample Preparation
 
Dissolving Graphite to Measure by ICP
Quartz Powder Preparation
XRF vs. ICP for Concrete Metals
Dissolution of Si in Metals
Analysis of Sediment Samples
Reactions of Sulfur and Bromine
Determination of As in Sediment
Matrices for Soil Preparation
Trace Metal Analysis of Air Condensate
Analyzing Cement
Determination of Hg in Sediment
Sample Size for Steel Analysis
Analyzing For Br by ICP
Analytical Tips for Tin
Analyzing Silicone Oils
Ashing Technique for Metals
Coal Sample Digestions
Ashing Procedure For Tin
Using Blue HDPE Containers
Sn and Tl Soil Extraction
Filter Papers for EPA Method 353.2
Determination of Hg in Biological Matrices
 
  Stability & Compatibility
 
Eliminating High and Erratic Blanks
HF in Multi-element Standards
Chemical Stability of Standards
Questions About Mo, Ti, and Hg
Overcoming Au Stability Issues
Contaminants of Ethanol in HDPE
Vegetable Oil Stability
ICP Multi-Element Solution Incompatibilities
Multi-Element Compatibility and Preparation
Stability of Mercury in Plastic Bottles
Cadmium, Lead, and Copper Stability
Diluted Blends of Single Element Standards
Incompatible Metals Within Solution
Stability of Oil Standards
 
  Measurement
 
Controlling Transpiration
Calculating Weighing Uncertainty
Expressing Sensitivity
As Line Interferences from Fe
Measurement Uncertainty
Positive Interference with Hg 202
Linearity Slope Variance
Mercury and Antimony Troubleshooting
Zn Interferences Upon the Na 330.237 nm Line
Aluminum, Beryllium, and Chromium Interferences
 
Measurement Uncertainty Technical Troubleshooter

Who is Paul Gaines?

Using an ICP instrument, Damon reported his method uncertainty as ±10%. To facilitate a higher degree of confidence, Damon's management asked him to report the standard deviation associated with his three triplicate measurements of the sample as his uncertainty or confidence in the number. Fearing this may not be the best approach, Damon sought Paul's advice on the measurement uncertainty associated with ICP.


IV Labs / Inorganic Ventures: White Background
 
From the desk of Paul Gaines, Ph.D. Dr. Paul Gaines
  RE: Measurement Uncertainty
Dear Damon,

     The measurement uncertainty is 2(SD)/1.716, where SD is the standard deviation. The 2 is referred to as the coverage factor and the 1.716 is the square root of 3 (for three measurements).

     The analytical community and quality standard community support the idea that all data should be reported with a defined uncertainty. A more realistic uncertainty is to include the uncertainty of the standard used for calibration and the weight and volume measurements made for the sample preparation. The standard deviations of each of these operations must be determined. Then the overall standard deviation should be calculated by taking the square root of the sum of the squares, instead of just the measurement standard deviation.

Thank you for contacting Inorganic Ventures. I hope this helps.

 
  Paul's signature
Paul R. Gaines, Ph.D.
Serving you in chemistry
 
IV Labs / Inorganic Ventures: White Background

An Inorganic Ventures feature - July 2003