Inorganic Ventures - We flex to your specs
Guide to Reliable Measurements  
 Home   Ordering   Tech Center  Inorganic Ventures and inorganic CRM's  Quotations  Inorganic Ventures and inorganic CRM's
Sign In | Register  Find out more on this analytical standards or certified reference material from IV Labs! Search   
 Guides & Articles   Periodic Table   Expert Advice    Links   Technical Support 
You are Here:  Tech Center > Expert Advice > Zn Interferences Upon the Na 330.237 nm Line
  General Applications
 
Certified Concentration of a Standard
Nitric Acid Oxidations
Two Methods for Certification
ICP-MS Sensitivity Optimization
Cleaning Quartzware
 
  Sample Preparation
 
Dissolving Graphite to Measure by ICP
Quartz Powder Preparation
XRF vs. ICP for Concrete Metals
Dissolution of Si in Metals
Analysis of Sediment Samples
Reactions of Sulfur and Bromine
Determination of As in Sediment
Matrices for Soil Preparation
Trace Metal Analysis of Air Condensate
Analyzing Cement
Determination of Hg in Sediment
Sample Size for Steel Analysis
Analyzing For Br by ICP
Analytical Tips for Tin
Analyzing Silicone Oils
Ashing Technique for Metals
Coal Sample Digestions
Ashing Procedure For Tin
Using Blue HDPE Containers
Sn and Tl Soil Extraction
Filter Papers for EPA Method 353.2
Determination of Hg in Biological Matrices
 
  Stability & Compatibility
 
Eliminating High and Erratic Blanks
HF in Multi-element Standards
Chemical Stability of Standards
Questions About Mo, Ti, and Hg
Overcoming Au Stability Issues
Contaminants of Ethanol in HDPE
Vegetable Oil Stability
ICP Multi-Element Solution Incompatibilities
Multi-Element Compatibility and Preparation
Stability of Mercury in Plastic Bottles
Cadmium, Lead, and Copper Stability
Diluted Blends of Single Element Standards
Incompatible Metals Within Solution
Stability of Oil Standards
 
  Measurement
 
Controlling Transpiration
Calculating Weighing Uncertainty
Expressing Sensitivity
As Line Interferences from Fe
Measurement Uncertainty
Positive Interference with Hg 202
Linearity Slope Variance
Mercury and Antimony Troubleshooting
Zn Interferences Upon the Na 330.237 nm Line
Aluminum, Beryllium, and Chromium Interferences
 
Zn Interferences Upon the Na 330.237 nm Line Technical Troubleshooter

Who is Paul Gaines?

Terri was analyzing samples for Sodium by ICP-OES using the 330.237 nm line at concentrations near the detection limit. She had trouble with the repeatability of the measurements. Terri noticed that our Analytical Periodic Table showed this line could be influenced by the presence of Zinc. She wanted to know more about this interference, as well as how she might improve the reliability of her measurements.


IV Labs / Inorganic Ventures: White Background
 
From the desk of Paul Gaines, Ph.D. Dr. Paul Gaines
  RE: Zn Interferences Upon the Na 330.237 nm Line
Dear Terri,

     When using the Na 330.237 nm line, Zn can interfere from the 330.259 nm Zn line. Any interference would be due to background correction problems. These result from the use of a background point for the Na 330.237 nm measurement that is on the "long" wavelength side of the Na line. Most instruments will be able to resolve the aforementioned lines, unless there is an amount of Zn that is ~ 10 times greater than the Na. If this is the case, you may experience some wing overlap difficulties and an increase in the Na intensity measurement from the Zn. Levels of Zn that are 0.01 times that of the Na level will cause background correction error if the background point is on the long wavelength (Zn) side of the Na line.

     When working very near the detection limit in matrices that may present difficulties with spectral interference, I find it very useful to extract the data from the actual spectral scans of the standards and samples. This process involves a justified lack in trust in the ability of the system software to make the proper determination of the intensity. We have not found any easy way, other than to manually obtain each spectrum and in some manner, depending upon the supporting software, make the background correction and a determination of the net intensity. This process is much slower, but the reliability of the data will be limited (to the ability of the instrument to detect Na at 330.237 nm). In addition, the sensitivity of the measurement may be improved through a reduction in the power applied to the plasma and an increase in the sample Ar.

I hope these suggestions are of help.

 
  Paul's signature
Paul R. Gaines, Ph.D.
Serving you in chemistry
 
IV Labs / Inorganic Ventures: White Background

An Inorganic Ventures feature - March 2002


DISCLAIMER  Advice offered by Dr. Gaines is intended for the individual posing the question. We urge you to contact us to verify whether these suggestions apply to your circumstances.
 Privacy Policy  |  Site Map   
  800-569-6799   •   732-901-1900
© 2008 Inorganic Ventures, Inc.. All rights reserved.